{"product_id":"steam-engine-controller-panel-set-professional-efficient-steam-generator-controller-panel-with-v1294-ym0901-3111240154911","title":"Steam Engine Controller Panel Set Professional Efficient Steam Generator Controller Panel with V1294-YM0901-3111240154911","description":"\u003cp\u003e1、APPLICATION: The professional steam engine controller panel is a device for monitoring and regulating the operating status of steam engines. 2、TEMPERATURE DISPLAY: The steam engine controller panel has a temperature display that shows the operating temperature of the steam engine to ensure operation within safe limits. 3、SIMPLE OPERATION: The steam engine controller panel allows the operator to easily view and control the operation of the steam engine to ensure that it is working safely and efficiently. 4、CONTROL BUTTONS: The professional steam generator controller has control buttons to regulate the start, stop, and adjustment operations of the steam engine. 5、TEMPERATURE: The current temperature is displayed by the digital tube of the control panel, ranging from 6°C to 60°C (43°F to 140°F), the information comes from the temperature sensor.\u003cbr\u003eSpecification\u003cbr\u003eItem Type: Steam Engine Controller Panel Set\u003cbr\u003eMaterial: Plastic. Stainless Steel\u003cbr\u003eWeight: Approx. 463g\/16.3oz\u003cbr\u003eVoltage: 220V\u003cbr\u003ePower: 3-24KW\u003cbr\u003eSize: Approx. 115x103mm \/ 4.53x4.06in\u003cbr\u003eApplicable Scene: Steam Room\u003cbr\u003eApplicable Equipment: Steam Generator, Steam Machine\u003cbr\u003eControl Time Range(Min): 1～60 or Long Term\u003cbr\u003eDisplay Temperature Range: 6～60°C(43℉～140℉)\u003cbr\u003eControl Temperature Range:35～55°C(95～131℉)\u003cbr\u003eKey Function and Operation\u003cbr\u003eON OFF: Control system ON OFF button. Press “ON OFF” key to turn on the system, the system will open the solenoid valve and start to feed water, when the water level reaches the required level, the system will start to heat (current temperature).\u003cbr\u003eWhen the water level reaches the required level, the system heating starts (when the current temperature meets the conditions), until the water level reaches the high water level when the solenoid valve closes and stops feeding water, the system enters the\u003cbr\u003eAutomatic work state, that is, according to the last set temperature and working time to start working automatically, or according to the default set temperature and working time to start\u003cbr\u003eThe system will start working automatically according to the last set temperature and working time, or start working according to the default set temperature and working time (restarting when the system is powered down) until it needs to be reset. Press the “ON OFF” key again, the system will be shut down manually and enter into the auto drainage state.\u003cbr\u003ePress “ON OFF” key again, the system will be manually shut down and enter into automatic drainage, and shut down after the drainage is finished.\u003cbr\u003eSET: Temperature and time setting key. The first time you press this key to set the temperature, at this time the digital tube and the left red LED are flashing to show the previous set temperature.\u003cbr\u003eWhen the system is restarted after power down, the default setting temperature of 43°C(109℉) will be displayed, then press “△” or “▽” to set the temperature.\u003cbr\u003eThen press “△” or “▽” key to rise or fall to the desired temperature, then press “SET” key to confirm and enter into the time setting, the system has set working time and no working time.\u003cbr\u003eThe system has two modes of setting the working time and not setting the working time (i.e. long term work), at this time, the digital tube and the red LED on the right side are blinking.\u003cbr\u003eAt this time, the digital tube and the red LED on the right side are flashing to show the set time in front or the default setting time of the system, which is 45 minutes (restarting after power down), or the countdown time left for the system to work.\u003cbr\u003e(when you need to extend the setting time during operation), then press “△” or “▽” key to increase or decrease the time to the desired length, or\u003cbr\u003ePress “△” key until the digital tube blinks to show “CH” code, and then press “SET” key to confirm, then the digital tube resumes to show the current temperature, if not confirmed, it will take 3 seconds.\u003cbr\u003eIf it is not confirmed, it will be confirmed automatically after 3 seconds and the digital tube will resume displaying the current temperature, after which the system will start counting down or working for a long time.\u003cbr\u003eAfter that, the system will start countdown or long time work. The temperature setting range of the system is from 35°C to 55°C, and the default setting temperature of the system is 43°C (109℉). The system defaults to a set temperature of 43°C (109°F).\u003cbr\u003eWhen the system is working for a long period of time (i.e. long time), the 5 red LEDs on the right side of the digital tube are all on and the top one is blinking. When the system is operated for a set length of time (i.e., long term), the\u003cbr\u003eWhen the system is operating for the set duration, the timer range is up to 60 minutes, and the default timer is 45 minutes.\u003cbr\u003ePAUSE: Pause key. Press this key to pause the heating, the heating indicator light is off, the keep warm indicator light is flashing, only the “ON\/OFF” button and “LIGHT” button can be used, other buttons can be used, other buttons can be used.\u003cbr\u003eOnly “ON\/OFF” button and “LIGHT” button can be used, other keys are invalid, if in the countdown state, the timing time to still enter the automatic drainage, shutdown program.\u003cbr\u003eIf you press the key again, it will exit the pause state.\u003cbr\u003eLIGHT: External light switch key. As long as the system has electricity, this key is used as the switch of external light.\u003cbr\u003e△:Increase key for temperature and time setting.\u003cbr\u003e▽:Decrease key for temperature and time setting.\u003cbr\u003ePanel prompt message:\u003cbr\u003e1) Temperature lower than 6°C(43℉): digital tube display “ -L ”, the message comes from temperature sensor.\u003cbr\u003e2) Temperature higher than 60°C(140℉): digital tube shows “ -H ”, the message comes from the temperature sensor, the electric heater will stop or can't be heated.\u003cbr\u003e3) Failure of water inlet and replenishment: The digital tube displays “-E”, when the water level is still not up to the required level 10 minutes after the system starts to work and opens the solenoid valve for water inlet, or when the system does not reach the required level after 3 minutes of automatic replenishment according to the program during the working period. Indicates that there is a fault in the water inlet or replenishment system, the system will stop water inlet and the electric heater will not heat or stop heating.\u003cbr\u003e4) Drainage: The digital tube displays “-d”, indicating that the system is automatically drained at the end of the working period (including the end of pressing the “ON OFF” key and the end of the timing time), and the system will be automatically shut down after the drainage is finished.\u003cbr\u003e5) telecommunication failure: the digital tube displays “EE”, indicating that the telecommunication failure between the controller and the main board.\u003cbr\u003e6) Heating: The three color LEDs on the left side of the panel show the identifier “Heating Status Pattern.\u003cbr\u003ei. If the electric heater is divided into two groups for heating (1-6 electric heaters): when the identifier is red or green, it indicates that the temperature is lower than the set temperature and two groups of electric heaters are working; when the identifier is blue, it indicates that the temperature has reached the set temperature and is between 2°C (4℉) and 2°C (4℉) higher than the set temperature, and one group of electric heaters is working. ii.\u003cbr\u003eii. If the electric heaters are divided into three groups (9 electric heaters): when the identifier is red, it indicates that the temperature is lower than the set temperature by 2°C (4℉), three groups of electric heaters will work; when the identifier is green, it indicates that the temperature is between 2°C (4℉) and 2°C (4℉) lower than the set temperature, two groups of electric heaters will work; when the identifier is blue, it indicates that the temperature has reached the set temperature and is higher than 2°C (4℉) higher than the set temperature, one group of electric heaters will work. One group of electric heaters works.\u003cbr\u003e7) Holding: The yellow LED light on the right side of the panel shows the identifier “Temperature Pattern”, when the temperature reaches 2°C (415℉) above the set temperature, all electric heaters stop working and the system is in holding state.\u003cbr\u003eThe control system is equipped with self diagnostic function, for some common problems, the controller displays codes to prompt the user, as shown in the table below:\u003cbr\u003eCode\u003cbr\u003eImplication\u003cbr\u003eMethods of diagnosis and exclusion\u003cbr\u003e－L\u003cbr\u003eThe temperature is below 6 ° C, and the information comes from the temperature sensor.\u003cbr\u003eCheck whether the temperature in the steam room is lower than 6 ° C, otherwise check whether the temperature sensor lead is properly connected. The code will disappear if the wire is connected or the steam room temperature rises above 6 ° C.\u003cbr\u003e－H\u003cbr\u003eIf the temperature is higher than 60 ° C, the information comes from the temperature sensor, and the electric heat pipe will stop or cannot be heated.\u003cbr\u003eCheck whether the steam room temperature is higher than 60 ° C, otherwise check whether the temperature sensor lead is short circuit. The code will disappear if the wire is connected or the steam room temperature drops below 60 ° C.\u003cbr\u003e－E\u003cbr\u003eIf water or water supply is faulty, the electric heat pipe will not heat or stop heating.\u003cbr\u003eCheck whether the water inlet solenoid valve is working, check the valve and magnetizer on the water source and pipeline, check whether the water level sensor connection line is rusted or not connected, and restart after cleaning, replacing or treating should feel the water.\u003cbr\u003eEE\u003cbr\u003eThe telecommunication between the panel and mainboard is faulty\u003cbr\u003eCheck whether the control cable between the mainboard and panel is open or short circuited, and whether the connector is properly inserted or whether the pin is bent.\u003cbr\u003ed or dd\u003cbr\u003eTime the time or press the \"ON OFF\" key, the machine into the automatic drainage, flushing and shutdown.\u003cbr\u003eNormal\u003cbr\u003eSetting Temperature: The temperature setting range is 35°C~55°C (95℉~131℉), the 5 red LEDs on the left side of the digital tube will display the set temperature by segments, the segments are as follows: 35°C (95℉) one lamp is on (the bottom one); 36°C~40°C (97℉~104℉) two lamps are on; 41°C~45°C (106℉~113℉) three lamps are on; 46°C～50°C(115℉～122℉) for four lamps on; 51°C～55°C(124℉～131℉) for all five lamps on. The system default setting temperature is 43°C(109℉).\u003cbr\u003eTiming: The maximum timing is 60 minutes, the 5 red LEDs on the right side of the digital tube show the remaining working time of the system in the following segments: 20 minutes or less for one lamp (the bottom one); 20-30 minutes for two lamps; 30-40 minutes for three lamps; 40-50 minutes for four lamps; 50-60 minutes for all five lamps. The system default setting time is 45 minutes. When the working time is not set (i.e., when working for a long period of time), the five red LEDs on the right side of the digital tube are all on and the top one is blinking.\u003cbr\u003ePackage List\u003cbr\u003e1 x Steam Engine Controller Panel\u003cbr\u003e1 x Temperature Sensor Cable\u003cbr\u003e1 x Control Cable\u003cbr\u003eNote\u003cbr\u003e1. The temperature sensor is mounted separately and led into the controller by connecting wires, which is suitable for the controller to be installed in and outside the steam room. It is recommended that the user choose to install the controller outside the steam room.2. Manual measurement please allow some error.\u003cbr\u003e\u003cbr\u003eProducts received faulty, damaged, or not as described are eligible for a return, refund, or replacement in accordance with local consumer laws. We are committed to ensuring all products meet the standards of quality and reliability expected by our customers. Please note that we do not accept returns or provide refunds for change of mind. We encourage you to carefully consider your purchase to ensure it meets your needs and expectations.\u003c\/p\u003e\u003cbr\u003e\u003cbr\u003e\u003cdiv\u003e \u003cstrong\u003ePostage Information\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eWe offer flat-rate postage rather than a postage calculator.\u003cbr\u003e\u003cbr\u003eFree postage applies to eligible metropolitan CBD addresses within 10 km of the CBD. This excludes Perth, Darwin, Hobart and the ACT.\u003cbr\u003e\u003cbr\u003eFor addresses outside the eligible free-postage area, an additional delivery charge may apply. Please contact us through \u003cstrong\u003eeBay Messages\u003c\/strong\u003e before purchasing to confirm the delivery charge for your address.\u003cbr\u003e\u003cbr\u003eAdditional delivery charges may apply to NT, regional WA, and remote, rural or outback areas.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eNew Zealand:\u003c\/strong\u003e Postage is not included.\u003c\/div\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eNote:\u003c\/b\u003e Please note that this item is dispatched form our warehouse in China.","brand":"Dropship Zone","offers":[{"title":"Default Title","offer_id":67590546981032,"sku":"V1294-YM0901-3111240154911","price":107.57,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0479\/5718\/0584\/files\/b8b6977dbedfeeb1d4cd1dea9aefe04e.jpg?v=1790839531","url":"https:\/\/zntswholesale.com.au\/products\/steam-engine-controller-panel-set-professional-efficient-steam-generator-controller-panel-with-v1294-ym0901-3111240154911","provider":"ZNTS Wholesale Australia","version":"1.0","type":"link"}