{"product_id":"clipsal-max9-rcbo-20a-30ma-240vac-5060hz-6000a-1p-n-type-a-slim-mx9r3120-v1202-9311554812713","title":"Clipsal Max9 RCBO 20A 30mA 240VAC 50\/60Hz 6000A 1P N Type A Slim MX9R3120 V1202-9311554812713","description":"\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eThis MAX9 product is a residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 20A In rated current at 30°C and C tripping curve. The operating frequency is 50Hz or 60Hz. The earth leakage protection class is type A with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 6000A at 240VAC. It has an electrical endurance going up to 10000 cycles and mechanical endurance going up to 20000 cycles. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. It brings safety, reliable solution for commercial and industrial applications with high breaking capacity. It has a RCM quality lable. The Ue rated operational voltage is 240VAC. The Ui rated insulation voltage is 440VAC. It has a Uimp rated impulse withstand voltage of 4kV. It can be mounted on DIN rail for modular installation. The width in 9mm pitches is 2. The dimensions are (W) 18mm x (H) 93mm x (D) 73mm. The product color is white (RAL9003). The product weight is 136g. According to IEC 60529 standard, the degree of protection is IP20. The pollution degree is 2. The operating temperature is from -25°C to +70°C. The storage temperature is from -40°C to +85°C. This product is complies with IEC 61009-2-2 and EN\/IEC 61009-1 standards.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDegree of protection (IP)\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnectable conductor cross section solid-core\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e1-16 mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNumber of protected poles\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePollution degree\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOver voltage category\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLeakage current type\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003eA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e240 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConnectable conductor cross section multi-wired\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e1-10 mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConcurrently switching neutral conductor\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWith interlocking device\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated fault current\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e30 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAnti-nuisance tripping version\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage type AC-DC\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003eAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWidth in number of modular spacings\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated short-circuit breaking capacity Icn according to EN 61009-1\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e6 kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent limiting class\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e20 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRelease characteristic\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003eC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNumber of poles (total)\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e440 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSurge current capacity\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e0.25 kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAmbient temperature during operating\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e-25-70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e4 kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFlush-mounted installation\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBuilt-in depth\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003e44 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisconnection characteristic\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003eUndelayed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan\u003eMax9\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003cp\u003eBrand: Clipsal\u003c\/p\u003e\n\u003cp\u003eManufacturer Part Number: MX9R3120\u003c\/p\u003e\n\u003cp\u003eBarcode: 9311554812713\u003c\/p\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e\u003cb\u003eNote: \u003c\/b\u003eWe don't use postage calculator but we offer a flat rate postage.\u003cbr\u003eFree shipping is for the capital cities CBD area only (10 kilometers form the CBD) excluding Perth, Darwin, Hobart and ACT. If your post code is not in CBD area, you can still place the order but our support team will contact you for the delivery cost which could be between $20 to $25 maximum for post codes near a capital city, $25 to $45 maximum for TAS and WA metro. Bulky items will attract extra cost. You can then decide to pay for the postage or cancel the order. You can contact us for NT, WA regional and remote\/outback\/rural areas for the postage quote. Postage to New Zealand is not included.\u003c\/span\u003e","brand":"Clipsal","offers":[{"title":"Default Title","offer_id":55499101536424,"sku":"V1202-9311554812713","price":85.2,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0479\/5718\/0584\/files\/53dd1431eb2762cd457911158afce0a7.webp?v=1778083638","url":"https:\/\/zntswholesale.com.au\/products\/clipsal-max9-rcbo-20a-30ma-240vac-5060hz-6000a-1p-n-type-a-slim-mx9r3120-v1202-9311554812713","provider":"ZNTS Wholesale Australia","version":"1.0","type":"link"}